12v digital timer. with independent relay. Automation, programmer or timer.
Great utility to automate any lighting or others. With different programs in which you can start a countdown, create an intermittent signal, etc.
Memory of the last configuration.
Independent relay: can work with any voltage independently.
Red illuminated numbers.
Operating voltage: 12VDC (10~16V)
Signal voltage: 4V~20V
Consumption: 20ma, operating current: 50ma.
Measure 65x35mm. Thickness counting with the relay 18mm
Instructions:
Button K1: If it is held for 2 seconds, the timer will let you choose between Program 1, 2, 3 and 4. Pressing button K2 will save the setting.
Button K2: By pressing this button, the digit of the hundreds, tens or units will flash, and by means of button K3 the figure will be changed.
Button K3: With this button we will change from hundredths of seconds to seconds or minutes.
By bridging IN and 12V+, it is possible to give the contact signal.
Program P-1: When a contact signal is given, the relay lets current flow for the time previously set. When the time is up, the relay turns OFF. And the program ends.
If while the program is running, you give it a contact signal, the program ends instantly, returning the relay status to OFF.
Program P-2: When a contact signal is given, the relay starts in OFF mode for the time previously configured. When the first time is over, the relay changes to ON mode and the second time starts. And the program ends.
Note that you can choose the relay ON time different from the relay OFF time. For this you have to set both times. By pressing the K2 button, you first select the 3 digits of relay OFF time, and then you need to select the 3 digits of relay ON time.
Program P-3: The program starts automatically when the timer takes power, without the need to bridge the contact signal. The relay starts in ON mode for the time previously programmed, and when the first time ends, the relay switches to OFF mode for the second configured time. And the program repeats itself infinitely.
Note that you can choose the relay ON time different from the relay OFF time. For this you have to set both times. By pressing the K2 button, you first select the 3 digits of relay ON time, and then you need to select the 3 digits of relay OFF time.
Program P-4: When a contact signal is given, the relay lets current flow for the time previously configured. When the time is up, the relay turns OFF. And the program ends.
If while the program is running, you give it a contact signal, the program starts counting from the beginning.